Equipment Module Will Not Operate |
- Make sure the spa control is plugged into the circuit
board of the equipment module.
- Check the main circuit breaker panel. If the GFCI or
circuit breaker has tripped, reset the breaker. If the
circuit breaker trips repeatedly, contact your dealer.
- Turn the circuit breaker, or switch, supplying power
to the equipment module OFF then ON.
- If the breaker continues
to trip, check with your electrician to be sure the proper
amperage breaker was installed.
|
Pump Will Run But There Is No Water Flow |
- Make sure all valves are in the open position.
- Make sure the filter is clean.
- Make sure the suction intake covers are free of debris.
- Make sure the water level of the spa is at least
2 inches above the skim filter.
- Check to make sure all adjustable
flow-type jets are turned open.
|
Pump Runs And There Is Water Flow But No Heat |
- Press the temperature set button to increase temperature.
Do NOT expect to feel hot water coming from the jets.
- Make sure all valves are open to allow full water flow
through the system. Limited water flow will NOT build enough
pressure to allow the heater to come on.
- Clean the filter to assure maximum water flow.
- The system
is equipped with a heater delay switch that will prevent
heater operation from occurring for approximately 20 seconds
after the pump starts. Make sure the pump has been operating
for at least 20 seconds.
|
Pulsating Or Minimal Water Flow In High Speed Mode |
- Make sure water level of the spa is at least 2-inches
above the skim filter.
- Be sure jets are turned open.
- Make sure all valves are open.
- Make sure the filter element is clean.
- Make sure the suction
intake covers are free of debris.
|
Blower Will Not Blow Air Into The Spa |
- Check air blower connections for leaks.
- Make sure the air blower is plugged into the air blower
receptacle located on the side of the equipment module.
- Make
sure air controls are turned to the open position.
|
Ozone Bubbles Not Coming Out Of Ozone Jet |
- Make sure the lever of the Diverter Valve (if equipped)
is not in the center position.
|
Pump Vibrates Excessively |
- Check for loose screws on equipment module face and bolts
attaching equipment module to frame.
- Make sure the spa is not touching or rubbing against
anything such as a deck rail, house, etc.
- Air may be trapped in the pump housing. Turn the pump
off. Slightly loosen the pump unions. With a towel covering
the area (water will splash) turn the pump on for 3-5 seconds
to bleed air out of the pump housing. Turn the pump off
and tighten the unions. Repeat if necessary.
- Make sure that
the spa has been installed on a properly supported surface.
|